Aller au contenu principal

    Calibration of an acoustic echo-integration system in a deep tank, with system gain comparisons over standard sphere material, water temperature and time

    Demander un document de réunion
    Numéro du document:
    WG-KRILL-92/17
    Auteur(s):
    D.A. Demer and R.P. Hewitt (USA)
    Accessibility Categories
    Open Access (OA)
    Point(s) de l'ordre du jour
    Résumé

    This paper outlines the theory and procedures for calibrating an echo integration acoustic system with a standard sphere. It presents the results of an extensive calibration of a Simrad EK500 scientific echo sounder with a 120 kHz sprit-beam transducer in a refrigerated 10m deep tank. Calibration parameters are studied in relation to sphere material (WC and Cu), water temperature (0.5-5.5°C), transmitted pulse length (0.1, 0.3, and 1.0 ms), target depth (0.8 - 7.5 m), and time (149 days). A discussion follows concerning the ramifications of calibration errors and variability on the accuracy of acoustic biomass estimation.